Parameter |
Specification |
|
Method of detection |
Mean Value |
|
Display |
LCD (Digital display:3200 counts)
LCD (Bar-graph display: 32 segments) |
|
Range Switching |
Auto-range |
|
Ambient Temperature and Humidity |
0 to 50°C
80% RH or less (no condensation) |
|
Temperature Coefficient |
0.05% of range/deg.C or less (within the ranges
of 0 to 18 deg.C and 28 to 50 deg.C for measurement of 0 to 50A). |
|
Influence of External Magnetic Field |
0.0005% typical 1 (on current value of adjacent
cable) |
|
Influence of Conductor Position |
Within accuracy |
|
Influence of residual current |
10mA or less in proximity to a 10mm-dia
conductor carrying 50Amps. |
|
Safety Standard |
EN61010-1, EN61010-2-032 (CAT III 300V) |
|
Circuit Voltage |
300Vrms or less |
|
Withstanding Voltage |
3.7kV AC for one minute |
|
Power Supply |
One CR2032 (Coin-shaped) 3V battery |
|
Battery Life |
Approx. 90 hours (continuous) |
|
Auto Power Off |
Approx. 10 minutes |
|
Diameter of Measurable Conductor |
40mm maximum |
|
Dimensions |
Approx. 70mm (W) x 176mm (H) x 25mm (D) |
|
Weight |
Approx. 200g |
|
Accessories |
Instruction manual, Battery and soft Carrying
Case |