Measuring
Range/Accuracy |
60 to 60000 minutes-1/0.1°/°° |
|
Temperature |
|
|
Pt100 |
-50°C
to +600°C/1°
+ sensor% |
|
NiCrNi (int) |
-50°C
to +100°C/0.5°
+ 3% |
|
(ext.) |
-50°C
to +100°C/0.5°
+ sensor% |
|
(ext.) |
100°C
to +1000°C/1°
+ sensor% |
|
|
|
|
Extra-low Voltage
(AC/DC) |
-9 to +9V/2% |
|
|
(R1=30kOhm,
with cable VIB 5.440) |
|
|
-30 to +30V/2% |
|
|
R1=100kOhm,
with cable VIB 5.434) |
|
|
|
|
Extra-low Current
(AC/DC) |
-20 to +20mA/2%; 4 to
20mA/2% |
|
|
(R shunt =
200 Ohm, with cable VIB 5.434) |
|
|
|
|
The following applies
to the internal sensor and external sensors (1µA/m-2
CLD1; 100mV/g ICP®)
and to external measuring instruments (1mV/ms-2): |
|
Displacement |
up to 9000
µm (p-p)/1% |
|
Velocity |
up to 9000 mm/s
(p-p)/1% |
|
Acceleration |
up to 6000 m/s2
(p-p)/1% |
|
Shock pulse |
up to 81 dBSV/3dB |
|
|
|
|
Fulfilled
standards
Frequency response according to ISO 2954 - other parameters and
measured variables according to
DIN 45662 class 1 |
| |
|
|
Noise, Internal
Sensor (from 10Hz) |
|
Velocity |
0.1mm/s eff. |
|
Displacement |
2µm
eff. (instrument + sensor) |
|
Shock pulse |
<0dBsv, peak value |
|
|
|
|
Compatibility |
External transducer |
|
Vibration |
• CurrentLineDrive (CLD): |
|
|
VIBCODE for
measurement studs with location recognition; |
|
|
TIPTECTOR hand-held
probe for vibration and shock pulse; |
|
|
Quick-fit transducer
for SPM measurement studs; |
|
|
Industrial
accelerometer with magnetic, screwed and glued connection, with |
|
|
adapter and hand-held
probe |
|
|
• ICP®-type accelerometerf |
|
|
• Velocity transducer (mV/mms-1) |
|
|
• Displacement transducer (mV/µm)e |
|
RPM |
• Optical sensor (passive/active) |
|
|
• 5V TTL (optical or inductive transducer) |
|
Temperature |
• NiCrNi (magnet/probe) |
|
|
• IR sensor |
|
|
• Pt100f |
|
|
|
|
CE Conformity |
For line lengths <3m |
|
interf. emission |
EN 50081-1
(residential area) |
|
interf. sensib. |
EN 50082-1
(residential area) |
|
|
<4% of measurement
value, or <double the noise value. |
|
|
|
|
Intrinsic Safety |
EEx em ib IIC T4: TÜV
01 ATEX 1699 |
|
|
U.S. equivalent NEC 505: Class 1, Zone
1, AEx em ib IIC, T4 |