289_200p.jpg - 18.84 Kb 

For Sale, Fluke 289 Logging Multimeter

New diagnostic functionality for maximizing productivity in the plant. The new 289 is the next generation high performance industrial logging multimeter designed to solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment. With the ability to log data and review it graphically on-screen, you can solve problems faster and help minimize downtime. Let the new 289 be your watchdog for systems or processes while you are off solving other problems

 
Voltage DC
Accuracy  0.025 %
Range and Resolution  50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Voltage AC
Accuracy  0.4 %(true-rms)
Range and Resolution  50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Current DC
Accuracy  0.06 %
Range and Resolution  500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Current AC
Accuracy  0.61 %(true-rms)
Range and Resolution  500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Temperature (excluding probe)
Accuracy  1.0 %
Range and Resolution  -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F)
Resistance
Accuracy  0.05 %
Range and Resolution  500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
Resistance 10 50 Ω (2 wire connection)
Accuracy  0.15 % + 20
Range and resolution  50.000 Ω
Capacitance
Accuracy  1.0 %
Range and Resolution  1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF Ω
Frequency
Accuracy  0.005% + 5
Range and Resolution  99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Additional functions/features
Multiple on-screen displays  Yes
True-rms AC bandwidth  100 kHz
DBV/dBm  Yes
DC mV resolution  1 μV
Megohm range  Up to 500 M
Conductance  50.00nS
Continuity beeper  Yes
Battery/Fuse access  Battery / Fuse
Peak  250 μS
Elapse time clock  Yes
Time of day clock  Yes
Min-Max-Avg  Yes
Frequency  Yes
Duty Cycle  0.01 % to 99.99 %
Pulse Width  0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
Hold  Yes
Isolated Optical Interface  Yes
Auto/Touch Hold  Yes
Reading memory  Yes
Log to PC  Yes
Interval/Event Logging  Yes
Logging Memory  Up to 10,000 readings
Resistance Low Ohm  0.001 Ω to 50.000 Ω 10 mA source
LoZ  Yes
Low Pass Filter  Yes
Call for a Price.