Powertech Rentals your One Stop Store for Test & Measurement and Telecommunication Test Equipment Rental and Sales

 
Current Injection > Mitton LCI-2058

Current Injection

   
Mitton LCI-2058 Low Current Injector Test Set  
 
Product Description
The Low Current Injector (LCI) provides a reliable method for testing earth/grounding systems, particularly those with low impedance (<2 ohms) or which are extensive and where noise is present on the earthing system. Portable earth testers are often unsuited to testing such earth/grounding systems due to limited test current and inadequate noise rejection.

The LCI 2058 provides a reliable and simple means to test power system earthing/grounding systems. The LCI 2052 is an off-frequency constant current source used to inject current into the earthing/grounding system under test.
 

Mitton LCI-2058 Low Current Injector Test Set

 

Applications
  • Earthing/grounding grid impedance measurement.
  • Suitable for small to large earthing/grounding systems.
  • Current splits measurement.
  • Induction testing.
  • Resistivity testing.

Features

  • Constant current (adjustable) 1 to 10A rms.
  • Fixed frequency, 58Hz for 50Hz systems (52Hz for 60Hz systems).
  • Solid state, no moving parts.
  • Auto cut-off.
  • Simple set up.
  • Portable (15kg).

Practical Testing of Grounding Systems by Current Injection (PDF)
(documents are in PDF format and will open in a new window)


Auto shut-off is a safety feature that ensures the injected current immediately ceases should the injection circuit be interrupted. The LCI output is galvanically isolated from the input supply.

In some cases it is impractical to use the LCI, for example where the injection is carried out using an existing power or transmission line running parallel to another line. In such cases the induced current in the test circuit may be excessive. However, a diesel genset can be used instead.
 

Specifications
Power Supply 230V 50/60Hz (mains or genset)
Output Current 1 to 10A constant current
Protection Auto shutdown on open circuit
Output Frequency 58Hz (50 Hz systems),  52Hz (60 Hz systems)
Housing Robust Pelican Case
Weight 17kg
 
 
Rental Inquiry Information
 

Reference:

LCI 2058

Description:

Mitton LCI 2058 Low Current Injector Test Set
 


Home | About Us | Product Category | Test & Communication | Mechanical Tools | Safety Items | Feedback | Search |
Test and Measurement Site Map | Telecommunications Site Map

8 Hasler Road

Powertech Rentals Pty Ltd

  70 Fison Avenue West
Osborne Park, WA 6017

A.B.N. 85 082 324 918

  Eagle Farm, Qld 4009
Ph: 61 8 9244 2855

1300 736 292

  Ph: 61 7 3268 1378
Fax:61 8 9244 4478

sales@powertech-rentals.com.au

  Fax: 61 7 3268 1374