Features
- Can measure large AC current up to 2000 Amps.
- Peak hold function.
- 55mm diameter large tear drop shaped jaws.
- Measure AC/DC volts.
- Resistance and continuity.
|
|
| Specifications |
|
|
|
0 to 400A |
50Hz to 60Hz |
±1%
of reading ±3 digits |
|
|
40Hz to 1kHz |
±2%
of reading ±3 digits |
|
0 to 1500A |
50Hz to 60Hz |
±1%
of reading ±3 digits |
|
|
40Hz to 1kHz |
±3%
of reading ±3 digits |
|
1500A to 2000A |
50Hz to 60Hz |
±3%
of reading |
|
|
|
|
40/400/750V |
50Hz to 60Hz |
±1%
of reading ±2 digits |
|
|
40Hz to 1kHz |
±1.5%
of reading ±3 digits |
|
|
|
|
40/400/1000V |
±1%
of reading ±2 digits |
|
|
Resistance |
|
40Ω/4kΩ/400kΩ |
±1.5%
of reading ±2 digits |
|
|
Continuity Buzzer |
Buzzer sounds below 50Ω
±35Ω |
|
|
DC400mV/200mV |
|
Conductor Size |
55mm diameter maximum |
|
Frequency Response |
40Hz to 1kHz |
|
Withstand Voltage |
5550V AC for 1 minute |
|
| |
| Safety Standard |
| |
| IEC 61010-1 |
CAT III |
600V |
| |
CAT II |
1000V |
| IEC 61010-2-031 |
|
|
| IEC 61010-2-032 |
|
|
|
|
| |
| General Specifications |
|
Power Source |
R6P (AA) 1.5V x 2 |
|
Dimensions |
247mm (L) x 105mm (W) x 40mm (D) |
|
Weight |
470g approx. |
|