Powertech Rentals your One Stop Store for Test & Measurement and Telecommunication Test Equipment Rental and Sales

 
Current Clamps > Hioki 3283

Current Clamps, Probes and Meters

 
Hioki 3283 Clamp-on AC Leakage Current Meter
 

Description
The 3283 Clamp-On Leak HiTester is designed for wide-range measurement on live circuits, from very small leakage currents up to load currents of 200 amperes. The clamp part is made of material with high magnetic permeability, to minimize adverse effects caused by external magnetic fields, and to reduce tolerances due to the position of the measured conductor.

High-sensitivity range with 10-mA full-scale point. Allows accurate measurement even of minute leakage currents (resolution 10µA).

Hioki 3283 Clamp-on 10mA to 200A AC rms Features
  • Wide bandwidth, 5Hz to 15kHz (Waveform output).
  • High-sensitivity with a full scale of 10mA (resolution 10µA).
  • High-accuracy at ±1%.
  • True RMS Measurement.
  • Analyzer functions, for filtering and output signals.

Microprocessor-controlled functions: In spite of the compact dimensions of the unit, versatile functions such as SLOW and MAX/MIN are made possible by the built-in microprocessor.

True rms indication: The true-rms conversion circuit delivers accurate results not affected by leakage current distortion.

Filtering: The widespread use of switching power supplies and equipment incorporating inverter technology frequently causes harmonics to be superimposed in the leakage current waveform. The filter in the 3283 allows two kinds of measurement, for leakage current caused by insulation faults and leakage currents including harmonics.

Specifications
 
AC Current Range 10.00 mA to 200 Amp, 5 ranges (±1.0% of reading ±5 digits at 50/60Hz), and
200 Amp, 1 range (±1.5% of reading ±5 digits at 50/60Hz), effective value rectifier.
AC Voltage Range None
Filter Function 180Hz ±30Hz/-3dB
Frequency Measurement 100.0 or 1000 Hz, 2 ranges (±0.3% of reading ±1 digit)
Analog Output DC or AC 1V/f.s, Level output: with REC mode, Waveform output: with MON mode.
Frequency Characteristics 40Hz to 2kHz (at AC current/voltage)
Display Section Digital/1000 digit,  Bargraph/35 segment
Sampling Rate 2 or 4 times/sec (Slow: 1 times/3 seconds)
Crest Factor (RMS) 2.5 (1.5 at 200Amp range)
Maximum Circuit Voltage 300 Volts AC rms (insulated wire)
Power Supply 6F22 (006P) x 1, Continuous use 40 hours, or AC adapter
Core Jaw Diameter 40mm (1.57 inches)
Dimensions 62mm (W) x 225mm (H) x 39mm (D), [2.44" (W) x 8.86" (H) x 1.54" (D)]
Weight 400gms (14.1 ozs)
 
Rental Inquiry Information

Reference:

3283

Description:

HIOKI 3283 Clamp-on Leakage HiTester
 
 


Home | About Us | Product Category | Test & Communication | Mechanical Tools | Safety Items | Feedback | Search |
Test and Measurement Site Map | Telecommunications Site Map

8 Hasler Road

Powertech Rentals Pty Ltd

  70 Fison Avenue West
Osborne Park, WA 6017

A.B.N. 85 082 324 918

  Eagle Farm, Qld 4009
Ph: 61 8 9244 2855

1300 736 292

  Ph: 61 7 3268 1378
Fax:61 8 9244 4478

sales@powertech-rentals.com.au

  Fax: 61 7 3268 1374