| Specifications |
|
DC Current Output
(Internal battery operation) |
Range and
Resolution
0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up).
Over-range to 24.000 mA
Drive Capability
12 V compliance, or 500 ohms @20 mA
Accuracy (% of span)
0.05 % |
|
DC Current
Simulate (External 24 volt loop supply) |
Range and
Resolution
0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up).
Over-range to 24.000 mA
Drive Capability
1000 ohms @20 mA
Accuracy (% of span)
0.05 % |
|
Current
Adjustment Modes |
Range and
Resolution
Manual: Coarse Fine: 25% step
Automatic: Slow Ramp, Fast Ramp, 25% step |
|
| |
| |
| Measurement Accuracy |
|
VDC |
Range and
Resolution:
400.0 mV, 4.000V, 40.00V, 400.0V, 1000V
Best Accuracy (% of reading + LSD):
0.1% + 1 |
VAC (true RMS)
to 1 kHz * |
Range and
Resolution:
400.0 mV, 4.000V, 40.00V, 400.0V, 1000V
Best Accuracy (% of reading + LSD):
0.7% + 2 |
|
mA DC |
Range and
Resolution:
30.000 mA
Best Accuracy (% of reading + LSD:
0.05% + 2 |
|
A DC |
Range and
Resolution:
1.000 A (0.440 A continuous)
Best Accuracy (% of reading + LSD):
0.2% + 2 |
|
A AC |
Range and
Resolution:
1.000 A (0.440 A continuous)
Best Accuracy (% of reading + LSD):
1% + 2 |
|
Resistance |
Range and
Resolution:
400.0 Ohms, 4.000 kOhms, 40.00 kOhms, 400.0 kOhms, 4.000 MOhms,
40.00MOhms
Best Accuracy (% of reading + LSD):
0.2% + 1 |
|
Frequency (0.5 Hz
to 20 kHz) |
Range and
Resolution:
199.99 Hz, 1999.9 Hz, 19.999 kHz, 199.99 kHz
Best Accuracy (% of reading + LSD):
0.005% + 1 |
|
Diode Test |
Range and
Resolution:
2.400 V (measures diode voltage drop)
Best Accuracy (% of reading + LSD):
2% + 1 |
|
Continuity |
Range and
Resolution
Beeps for resistance < approx. 100 ohms |
|
| |
| |
| General Specifications |
|
Maximum voltage
applied between any jack and Earth Ground |
1000 V rms |
|
Storage
Temperature |
-40 ēC to 60 ēC |
|
Operating
Temperature |
-20 ēC to 55 ēC |
|
Temperature
Coefficient |
0.05 x (specified
accuracy) per ēC (for temperatures < 18 ēC or > 28 ēC) |
|
Relative Humidity |
95% up to 30 ēC; 75%
up to 40 ēC; 45% up to 50 ēC; 35% up to 55 ēC |
|
Vibration |
Random, 2g, 5-500 Hz |
|
Shock |
1 meter drop test |
|
Safety |
Designed in
accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2
No. 1010.1-92 Overvoltage Category III |
|
Size |
32 mm H x 87 mm W x
187 mm L (1.25 in H x 3.41 in W x 7.35 in L) |
|
Size, with
holster and Flex-Stand |
52 mm H x 98 mm W x
201 mm L (2.06 in H x 3.86 in W x 7.93 in L) |
|
Weight |
369 g (13 oz); with
holster and Flex-Stand 638 g (22.5 oz) |
|
Battery |
Single 9V Alkaline
battery (ANSI/NEDA 1604A or IEC 6LR61) |
|
Battery Life |
50 hours typical
(measurement), 12 hours typical (sourcing 12 mA) |
|
Warranty |
3 years |
|
| |
| Rental Inquiry Information |
| |
|
Reference: |
787 |
|
Description: |
Fluke 787 Process Meter/Loop Calibrator |
| |
|
|