Powertech Rentals your One Stop Store for Test & Measurement and Telecommunication Test Equipment Rental and Sales

 
Power Quality Analyzers > Model 41B

Power Quality Analyzers

 
Fluke 41B Power Harmonics Meter
 

The model 41B Displays updates three times a second for a dynamic view of actual circuit conditions, it Measure rms, peak and total harmonic distortion (THD) for complex voltages and currents - with no manual calculations required.

Fluke 41B Power Harmonics Meter

Features
  • True-rms voltage - 5.00V to 600V ac/dc.
  • True-rms current - 1.00mV(A) to 1000mV(A) ac/dc.
  • Active power, apparent power (VA), reactive power (VAR) and power factor (PF).
  • Total harmonic distribution, harmonics to 31st and
    K-factor.
  • Memory for 8 complete data sets.
  • FlukeView® PC software for Windows® and DOS included.
  • Data Logging.
  • Optically isolated RS-232 interface.

 

 

 
Specifications

Voltage
(add 2 digits if <15V rms)

 

Range:
 

5.0V to 600V rms (AC + DC)
±5.0V to ±933V Peak

Accuracy:
 

±(0.5% +2 digits) (Peak)
±(2% +3 digits) (DC)

Current
(1mV/A) Isolated input

 

Range:

1.00mv(A) to 1000mV(A) rms (AC + DC)
±1.0mV(A) to ±2000mV(A) peak

Accuracy:
 

±(0.5% + 3 digits)+ probe specs (Peak)
±(2% + 4 digits) + probe specs (DC)

Watts/Volt-Amps
(1mV/A) Isolated input

Range:
 

0.0W(VA) to 600kW(kVA) average
0.0W(VA) to ±2000kW(kVA) peak

Accuracy:

AC + DC: ±(1% + 4 digits) + probe specs

Harmonics
(harmonic level >5% using Smooth 20)

Volts
 

 Volts Range:

Fundamental to 13th

Accuracy:

±(2%+2 digits) at 31st ±(8%+2 digits)

Amps
 

 Amps Range:

Fundamental to 13th

Accuracy:

Accuracy: ±(3%+3 digits) + probe specs

Watts
 

 Range:

at 31st

Accuracy:

±(3%+3 digits) + probe specs

Frequency
 

 Range:

5.0 Hz to 99.9 Hz

Accuracy:

±0.3 Hz

Input Bandwidth

Range:

DC, 5Hz to 2.1kHz

Crest Factor (CF)
 

 Range:

1.00 to 5.00

Accuracy:

±4%

Power Factor (PF)

 Range:

0.00 to 1.00

Accuracy:

±0.02

COSų (DPF)

 

 Range:

0.00 to 1.00

Accuracy:
 

±0.04 to ±0.03 (0.30 to 0.89)
±0.02 (0.90 to 1.00)

K-Factor (KF)

 Range:

1.0 to 30.00

Accuracy:

±10%

% THD

 Range:

0.00% to 100%

Accuracy:

±(0.03% of Reading + 2.0%)

 
 
General Specifications

Frequency range, fundamental

6-65 Hz and DC.
 

Minimum input levels

5 Volts rms or 1Amp rms.

Battery life

4 alkaline "C" cells (supplied) 48 hours typical (continuous).

Shock & Vibration

Per MIL-T-28800, Class 3.

Case

Drip-proof and Dust-proof per IEC, IP 52.

Size

234mm (L) x 100mm (W) x 64mm (D)

Weight

0.9kg

 
Rental Inquiry Information
 

Reference:

41B

Description:

Fluke 41B Power Harmonics Meter
 


Home | About Us | Product Category | Test & Communication | Mechanical Tools | Safety Items | Feedback | Search |
Test and Measurement Site Map | Telecommunications Site Map

8 Hasler Road

Powertech Rentals Pty Ltd

  70 Fison Avenue West
Osborne Park, WA 6017

A.B.N. 85 082 324 918

  Eagle Farm, Qld 4009
Ph: 61 8 9244 2855

1300 736 292

  Ph: 61 7 3268 1378
Fax:61 8 9244 4478

sales@powertech-rentals.com.au

  Fax: 61 7 3268 1374