Voltage
(add 2 digits if <15V rms)
|
|
Range:
|
5.0V to 600V rms (AC + DC)
±5.0V to ±933V Peak |
|
Accuracy:
|
±(0.5% +2 digits) (Peak)
±(2% +3 digits) (DC) |
|
|
Current
(1mV/A) Isolated input
|
|
Range: |
1.00mv(A) to 1000mV(A) rms (AC +
DC)
±1.0mV(A) to ±2000mV(A) peak |
|
Accuracy:
|
±(0.5% + 3 digits)+ probe specs (Peak)
±(2% + 4 digits) + probe specs (DC) |
|
|
Watts/Volt-Amps
(1mV/A) Isolated input |
|
Range:
|
0.0W(VA) to 600kW(kVA) average
0.0W(VA) to ±2000kW(kVA) peak |
|
Accuracy: |
AC
+ DC: ±(1% + 4 digits) + probe specs |
|
|
Harmonics
(harmonic level >5% using Smooth 20) |
|
Volts
|
|
Volts Range: |
Fundamental to 13th |
|
Accuracy: |
±(2%+2 digits) at 31st ±(8%+2 digits) |
|
|
Amps
|
|
Amps Range: |
Fundamental to 13th |
|
Accuracy: |
Accuracy: ±(3%+3 digits) + probe specs |
|
|
Watts
|
|
Range: |
at
31st |
|
Accuracy: |
±(3%+3 digits) + probe specs |
|
|
Frequency
|
|
Range: |
5.0 Hz to 99.9 Hz |
|
Accuracy: |
±0.3 Hz |
|
|
Input Bandwidth |
|
|
Crest Factor (CF)
|
|
Range: |
1.00 to 5.00 |
|
Accuracy: |
±4% |
|
|
Power Factor (PF) |
|
Range: |
0.00 to 1.00 |
|
Accuracy: |
±0.02 |
|
|
COSų (DPF)
|
|
Range: |
0.00 to 1.00 |
|
Accuracy:
|
±0.04 to ±0.03
(0.30 to 0.89)
±0.02 (0.90 to 1.00) |
|
|
K-Factor (KF) |
|
Range: |
1.0 to 30.00 |
|
Accuracy: |
±10% |
|
|
% THD |
|
Range: |
0.00% to 100% |
|
Accuracy: |
±(0.03% of Reading + 2.0%) |
|