The 1652 tester verify the safety of electrical installations in
domestic, commercial and industrial applications.
It can ensure that fixed wiring is safe and correctly installed to
meet the requirements of IEC 60364, HD 384 and all relevant local
standards. The unique ergonomic design, low weight, and padded
neck-strap to free your hands, make operating the Fluke 1652
multifunction tester a pleasure. With easy-to-operate controls and a
large display with exceptionally wide viewing angle, it's also
comfortable and safe to use.
|
 |
Features/Benefits
- Performs all basic installation tests including
continuity/insulation/loop impedance and RCD tripping time.
- Also provides RCD tripping current level and RCD auto-testing.
- Performs earth resistance and phase sequence measurement.
|
|
| Specifications |
|
AC Voltage Measurement
|
Range |
500 V |
|
Resolution |
0.1 V |
|
Accuracy |
0.8% + 3
(50 - 60 Hz) |
|
Input Impedance |
3.3 MW |
|
Overload Protection |
660 Vrms |
|
Continuity Testing |
Range (autoranging) |
20 W,
200 W, 2000 W |
|
Resolution |
0.01 W, 0.1
W, 1 W |
|
Test Current |
> 200 mA |
|
Open Circuit Voltage |
> 4 V |
|
Accuracy |
± (1.5%+3 digits) |
|
| |
| |
Insulation Resistance Measurement
|
Measurement |
Test
Voltage |
250 - 500 - 1000 V |
|
Resolution of Test Voltage |
+10% , -0%
(rated at test current) |
|
|
Test
Voltage |
50 V |
|
Test
Current |
1 mA @ 50 kW |
|
Insulation |
10 kW - 50 MW |
|
Resolution
Resistance Range |
0.01 MW |
|
Accuracy |
± (3% + 3 digits) |
|
|
|
Test
Voltage |
100 V |
|
Test
Current |
1 mA @ 100 kW |
|
Insulation |
100 kW - 20 MW |
|
Resolution
Resistance Range |
0.01 MW |
|
Accuracy |
± (3% + 3 digits) |
|
Insulation |
20 MW - 100 MW |
|
Resolution
Resistance Range |
0.1 MW |
|
Accuracy |
± (3% + 3 digits) |
|
|
|
Test
Voltage |
250 V |
|
Test
Current |
1 mA @ 250 kW |
|
Insulation |
100 kW - 200 MW |
|
Resolution
Resistance Range |
0.1 MW |
|
Accuracy |
± (1.5% + 3 digits) |
|
|
|
Test
Voltage |
500 V |
|
Test
Current |
1 mA @ 500 kW |
|
Insulation |
100 kW - 200 MW |
|
Resolution
Resistance Range |
0.1 MW |
|
Accuracy |
± (1.5% + 3 digits) |
|
Insulation |
200 MW - 500 MW |
|
Resolution
Resistance Range |
1 MW |
|
Accuracy |
10% |
|
|
|
Test
Voltage |
1000 V |
|
Test
Current |
1 mA @ 1 MW |
|
Insulation |
100 kW - 200 MW |
|
Resolution
Resistance Range |
0.1 MW |
|
Accuracy |
± (1.5% + 3 digits) |
|
Insulation |
200 MW - 500 MW |
|
Resolution
Resistance Range |
1 MW |
|
Accuracy |
10% |
|
|
|
Auto Discharge
|
Discharge time constant, 0.5 second
for C = 1 µF or less |
|
Live Circuit Detection
|
Inhibits test if terminal
voltage > 30 V prior to initiation of test |
|
Maximum Capacitive Load |
Operable with the 5 µF load |
|
| |
| |
| Loop Impedance Measurement |
| Measurement Range |
Range |
100 - 500 VAC (50/60 Hz) |
|
Input connection |
Soft Key selection |
|
Loop impedance |
Phase to earth |
|
Line impedance |
Phase to neutral |
|
Limit on consecutive tests |
|
|
|
|
Range |
20 W |
|
Resolution |
0.01 W |
|
Accuracy |
±(3% + 10 digits) |
|
|
|
Range |
200 W |
|
Resolution |
0.1 W |
|
Accuracy |
±(3% + 10 digits) |
|
|
|
Range |
2000 W |
|
Resolution |
1 W |
|
Accuracy |
±(3% + 10 digits) |
|
| |
|
PFC, PSC Test |
Computation
|
PFC or PSC determined by dividing
measured mains voltage by measured loop (L-PE) resistance or line
(L-N) resistance |
|
Range |
0 - 25 kA |
|
Resolution (Ik < 1000 A) |
1 A |
|
Resolution (Ik >= 1000 A) |
0.1 kA |
|
Accuracy
|
Determined by accuracy of loop resistance
and mains voltage measurements. |
|
RCD Testing |
|
²AC, G, S, A |
|
| |
|
Tripping Time Test (ΔT) |
Trip Time Accuracy |
±(1% Reading + 1 digit) |
|
|
|
Multiplier |
x ½ |
|
Current Settings |
10, 30, 100, 300, 500, 1000 mA |
|
Current Accuracy |
+0% - 10% |
|
|
|
RCD Type |
²G |
|
Measurement Range (EU) |
310 ms |
|
Measurement Range (UK) |
2000 ms |
|
|
|
RCD Type: |
²S |
|
Measurement Range (EU) |
510 ms |
|
Measurement Range (UK) |
2000 ms |
|
|
|
Multiplier |
x 1 |
|
Current Settings |
10, 30, 100, 300, 500, 1000 mA |
|
Current Accuracy |
+10% - 0% |
|
|
|
RCD Type |
²G |
|
Measurement Range (EU) |
310 ms |
|
Measurement Range (UK) |
310 ms |
|
|
|
RCD Type: |
²S |
|
Measurement Range (EU) |
510 ms |
|
Measurement Range (UK) |
510 ms |
|
|
|
Multiplier |
x 5 |
|
Current Settings |
10, 30 mA |
|
Current Accuracy |
±10% |
|
|
|
RCD Type |
²G |
|
Measurement Range (EU) |
50 ms |
|
Measurement Range (UK) |
50 ms |
|
|
|
RCD Type: |
²S |
|
Measurement Range (EU) |
160 ms |
|
Measurement Range (UK) |
160 ms |
|
| |
|
Tripping Current (ramp) Test -
|
Current Range |
50% - 110% of RCD's rated current |
|
Step Size |
10% of IΔN |
|
Dwell time (Type ²G) |
300 ms / step |
|
Dwell time (Type ²S) |
500 ms / step |
|
Trip Current Measurement Accuracy |
±5%
|
|
| |
|
² RCD Types |
G |
General, no delay |
|
S |
Time delay |
|
A |
Responds to pulsed signal |
|
AC |
Responds to AC |
|
| |
| |
| General Specifications |
|
Size |
(L x W x H): 10 x 25 x 12.5 cm |
|
Weight |
1.17
kg |
|
Batteries |
Type AA: 6 |
|
Warranty |
3
years |
|
Battery type |
Alkaline supplied, usable with 1.2V NiCD or NiMH rechargeable
batteries |
|
| |
| |
| Rental Inquiry Information |
| |
|
Reference: |
1652 |
|
Description: |
Fluke 1652 Installation Tester |
| |
|