As simple as one-two-three.
In today’s complex systems, a meter measurement just doesn’t give
enough detail to determine the cause of a fault. Signal anomalies,
dropouts and glitches that might cause a machine to go down, are
best displayed with an oscilloscope. The ScopeMeter 123 meet
today’s need of simultaneously measuring and checking waveforms.
The unique Connect-and-View™ triggering automatically displays
stable waveforms of virtually any signal. It really is as easy as
one-two-three!
|

|

Features
-
Connect-and-View™ hands-off operation for checking an
entire troubleshooting sequence without ever touching a button.
-
Checks
and troubleshoots AC and DC motor drives, sensors and
actuators, line voltage, transformers and converters, analog and
digital control loops.
-
Single,
shielded test lead measures all functions for intuitive
ease of use.
-
Fits
easily in your hand - just 2.5 lb./1.2 kg.
-
Safety-designed and certified for measurements on
600Vdc, 600 Vac rms/(1700Vpk-pk) CAT III industrial power
systems.
- Bandwidth
20 MHz digital oscilloscope.
- Two 5,000
counts true-RMS digital multimeters.
-
A dual-input TrendPlot™ recorder.
-
Shielded test leads for oscilloscope,
resistance and continuity measurements.
- Up to 7
hours battery operation.
- Optically
isolated RS-232 interface.
- Rugged,
compact case.
|
|
| Specifications |
|
Oscilloscope
Bandwidth |
20 MHz |
|
Dual input
True RMS Meter |
Vdc, Vac, Vac+Vdc,
Ohms, Continuity, Diode Test
Current, °C, °F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and
Zeroset |
|
TrendPlot
Recording |
Automatic vertical
scaling and time compression.
Display the actual, MIN, MAX and AVG reading. |
|
Real-time
sample rate |
25 MS/s |
|
Inputs and
digitizers |
2 |
|
Timebase
range |
10 ns - 1 min/div |
|
Input
sensitivity |
5 mV - 500 V/div |
|
Trigger
types |
Connect-and-View™,
Free Run, Single Shot, Edge, Video, External |
|
Glitch
capture |
40 ns |
|
Scope
measurements |
Automatic:
26 |
|
Maximum
record length |
512 min/max pts per
input |
|
Memory |
10
screens and setups |
|
| |
| |
| Environmental Specifications |
|
Operating Temperature |
0 ºC to 50 ºC
|
|
Storage Temperature |
-20 °C to +60 °C |
|
Operating Altitude |
3,000 meters |
|
| |
| |
| Safety Specifications |
|
Electrical Safety |
600V
CAT III (EN61010-1) |
|
| |
| |
| General Specifications |
|
Size |
232mm x 115mm x 50 mm |
|
Weight |
1.2
kg |
|
Warranty |
3
years parts and labor (one year on accessories) |
|
Battery life |
5
hrs using NiCAD |
RS-232 Interface
|
Optically isolated via optional PM9080 for interfacing to Printer or
PC. |
|
| |
| Rental Inquiry Information |
| |
|
Reference: |
123 |
|
Description: |
Fluke 123 ScopeMeter |
| |
|
|