Input Voltage
|
210 to 265 Volts 50/60Hz (single-phase)
|
|
Output Voltage
|
Sinusoidal: 0 - 90 kV peak, Symmetrical, 64kV RMS
DC±: 0 - 90 kV
Accuracy ±1%
|
|
Output Current
|
0 - 40 mA (Resolution 1µA)
Accuracy ±1%
|
|
Resistance Range
|
0.1 MΩ to 5GΩ
|
|
Output Frequency
|
0.01 ..... 0.1Hz in steps of 0.01Hz
|
|
Output Load
|
1.0μF @ 0.1Hz @ 64kV RMS (Approx 3,300m / 11,000ft of cable)*
1,2μF @ 0.1Hz @ 57kV RMS (Approx 3,600m / 12,000ft of cable)*
10μF @ 0.01 Hz @ 64kV RMS (Approx 33,000m / 100,000ft of cable)*
10μF Maximum Capacitance
* Based on a typical cable: 100pF/ft or 300pF/m
|
|
Output Modes
|
AC Hipot (VLF) Symmetrical and load independent across full range
DC positive and negative polarity
Burn/Fault Condition or Fault Trip Mode
Jacket/Sheath Testing
|
|
Memory
|
Up to 50 test records stored in non-volatile built in memory
|
|
Metering
|
Output Voltage and Current (true rms and peak)
Capacitance, Resistance, Time, Flashover Voltage
|
|
Weight
|
127kg/280lbs
|
|
Computer Interface
|
RS-232 connection (software included)
|
|
Dimensions
|
25.6"x 17.5"x 24"
(650cm x 445cm x 610cm)
|