Input Voltage
|
88 to 264 Volts 50/60Hz (single-phase)
|
|
Output Voltage
|
Sinusoidal: 0 - 60 kV peak
DC±: 0 - 60 kV
Accuracy ±1%
|
|
Output Current
|
0 - 50 mA (Resolution 1µA)
Accuracy ±1%
|
|
Resistance Range
|
0.1 MΩ to 20GΩ
|
|
Output Frequency
|
0.02 ..... 0.1Hz in steps of 0.01Hz
|
|
Output Load
|
1.0μF at 0.1Hz at 43kV rms (approx 3km of cable)*
2.0μF at 0.05Hz at 43kV rms (approx 6km of cable)*
5.0μF at 0.02Hz at 43kV rms (approx 15km of cable)*
50μF at reduced voltage and/or frequency
* based on a cable capacitance 330pF/metre
|
|
Output Modes
|
AC Hipot (VLF) Symmetrical and load independent across full range
DC positive and negative polarity
Burn/Fault Condition or Fault Trip Mode
Jacket/Sheath Testing
|
|
Memory
|
Up to 50 test records stored in non-volatile built in memory
|
|
Metering
|
Output Voltage and Current (true rms and peak)
Capacitance, Resistance, Time, Flashover Voltage
|
|
Weight
|
132 lbs (59.8 kg)
|
|
Computer Interface
|
RS-232 connection (software included)
|
|
Dimensions
|
18" (L) x 14" (W) x 20" (H)
(450mm x 350mm x 510mm)
|