Yokogawa CW240 Power Quality Analyzer

Yokogawa_CW240.jpg

Features

  • Electric power analysis and power supply quality control in a single unit.
  • Simultaneous measurement of loads in four systems (common to voltage).
  • Wide measurement range.
  • Leakage current measurement in four channels.
  • Wiring and setting check function.
  • Simultaneous measurement of power, harmonics, voltage fluctuations and waveforms.
  • Supports currents ranging from 200.0mA to 3000A and voltages up to 1000V
  • External memory. Can generate a screen hard copy. Can save data with an instantaneous value from one cycle (one waveform).
  • Large LCD. Can display vector diagrams of connections or waveforms of instantaneous values in addition to measured values.

Model CW240 Datasheet (PDF)
(documents are in PDF format and will open in a new window)

Specifications

Voltage Range

150.0/300.0/600.0/1000V

 

Current Range

96030 (2A)

200.0/500.0mA/1.000/2.000A

 

96033 (50A)

5.000/10.00/20.00/50.00A

 

96030 (200A)

20.00/50.00/100.0/200.0A

 

96031 (500A)

50.00/100.0/200.0/500.0A

 

96032 (1000A)

200.0/500.0A/1.000kA

 

96034 3000A range

300.0/750.0A/1.500/3.000kA

 

96034 2000A range

200.0/500.0A/1.000/2.000kA

 

96034 1000A range

100.0/200.0/500.0A/1.000kA

 

96035 3000A range

300.0/750.0A/1.500/3.000kA

 

96035 300A range

30.00/75.00/150.0/300.0A

Phase/Wiring Measurement


 

1P2W/IP3W/1P3W3i (Neutral line current)
3P3W2i (2 watt metered method) 3P3W3i (3 watt meter method)
3P4W/3P4W4i (Neutral line current)
SCOTT wiring (1P3W + 3P3W)

Number on Measurement System (Common Voltage)
 

1P2W
1P3W
3P3W2i

4 system load
2 system load
2 system load

Measurement Mode

Frequency, Electric Energy, Demand, Harmonics, Voltage Function, Waveform

Data saving

PC Card note 1., Internal Memory (1mByte)

Save Data
 

Standard Interval: 1/2/5/10/15/30 sec, 1/2/5/10/15/30/60 min note 2
Short Time Interval: 0.1/0.2/0.5 second for each waveform note 3.

 
Note 1. PC cards purchased from Yokogawa should be used for the CW240.
Note 2. Less than 30 second interval, impossible to output/print for harmonics measurement and waveform data.
Note 3. Data output item is only instantaneous value.
 
General Specifications

External Dimensions

Approx. 206mm (W) x 184mm (H) x 65mm (D)

Weight

Approx. 1.2kg (batteries not included)

Power Supply

AC adapter 100V to 240V AC (supplied)

 

Qty. 6 AA size alkaline batteries (supplied)

Optional Power Supply

NiMH rechargeable battery

 
Rental Inquiry Information
 

Reference:

CW240

Description:

Yokogawa CW240 Power Quality Analyzer